{"id":1597,"date":"2020-08-12T11:38:00","date_gmt":"2020-08-12T03:38:00","guid":{"rendered":"https:\/\/www.zuranceshi.com\/?p=1597"},"modified":"2021-04-02T23:40:07","modified_gmt":"2021-04-02T15:40:07","slug":"%e9%a6%99%e6%b8%af%e5%bb%ba%e7%ad%91%e9%98%b2%e7%81%ab%e8%a7%84%e8%8c%83-code","status":"publish","type":"post","link":"https:\/\/www.zuranceshi.com\/?p=1597","title":{"rendered":"\u9999\u6e2f\u5efa\u7b51\u9632\u706b\u89c4\u8303 code"},"content":{"rendered":"\n<p>Code of Practice for Fire Safety in Buildings<\/p>\n\n\n\n<p>\u9999\u6e2f\u5efa\u7b51\u9632\u706b\u89c4\u83032011 \u5e74\u5efa\u7b51\u7269\u6d88\u9632\u5b89\u5168\u5b88\u5219 (2015\u5e7410\u6708\u7248\u672c)<br><a href=\"https:\/\/www.bd.gov.hk\/sc\/resources\/codes-and-references\/codes-and-design-manuals\/index.html\" rel=\"noreferrer noopener\" target=\"_blank\">https:\/\/www.bd.gov.hk\/sc\/resources\/codes-and-references\/codes-and-design-manuals\/index.html<\/a><\/p>\n\n\n\n<p>\u9999\u6e2f\u7684\u9632\u706b\u95e8\u89c4\u8303\u5f15\u81ea\u9999\u6e2f\u623f\u5c4b\u7f72\u7684\u5efa\u7b51\u9632\u706b\u89c4\u8303\uff0c\u5373Code of Practice for Fire Safety in Buildings\uff0c\u76ee\u524d\u7684\u7248\u672c\u662f2011\u3002\u9999\u6e2f\u7531\u4e8e\u5386\u53f2\u7684\u539f\u56e0\uff0c\u4e00\u76f4\u4f7f\u7528\u82f1\u56fd\u7684\u6cd5\u89c4\u6807\u51c6\uff0c\u5373\u4f7f\u56de\u5f52\u4ee5\u540e\uff0c\u4ee5\u6ca1\u6709\u4f7f\u7528GB\u56fd\u6807\u3002\u9999\u6e2f\u4e5f\u6ca1\u6709\u81ea\u5df1\u7814\u53d1\u548c\u89c4\u5b9a\u72ec\u6709\u7684\u9632\u706b\u95e8\u6d4b\u8bd5\u65b9\u6cd5\uff0c\u76ee\u524d\u662f\u53c2\u7167\u6b27\u6807\u7684\u6d4b\u8bd5\u65b9\u6cd5\uff0c\u4f46\u4e5f\u8fd8\u662f\u5141\u8bb8\u4ee5\u524d\u7684\u82f1\u6807\u6d4b\u8bd5\u65b9\u6cd5\u3002\u5982\u4e0b\u89c4\u5b9a\u5f15\u81ea\u4e0a\u8ff0\u9999\u6e2f\u623f\u5c4b\u7f72\u7684\u5efa\u7b51\u9632\u706b\u6cd5\u89c4\uff1aSubsection E5 &#8211; Openings in Fire Barriers (Doors, Windows, Shutters and associated Penetrations)Clause E5.1&nbsp;Elements that protect openings, such as doors, windows and fire shutters in fire barriers should be tested in accordance with one of the following standards to demonstrate the required FRR (integrity and insulation as appropriate):\u5373\uff0c\u9632\u706b\u95e8\u5f15\u7528\u5982\u4e0b\u6b27\u6d32\u6807\u51c6\uff1a(a) BS EN 1634-1:2008, Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware. Fire resistance test for doors, shutters and openable windows ;(b) BS EN 1634-2:2008, Fire resistance tests for door, shutter and openable window assemblies and elements of building hardware. Fire resistance characterisation test for elements of building hardware;(c) BS EN 1634-3:2004, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware.Smoke control test for door and shutter assemblies;(d) BS EN 14600:2005, Doorsets and openable windows with fire resisting and \/or smoke control characteristics. Requirements and classification.Clause E5.2&nbsp;\u5982\u679c\u4e0b\u5217\u82f1\u56fdBS\u6807\u51c6\u6ca1\u6709\u88ab\u53d6\u4ee3\uff0c\u5219\u4e5f\u8ba4\u53ef\u3002\u5373\u4ee5\u524d\u6309\u82f1\u6807\u6d4b\u8bd5\u7684\u9632\u706b\u95e8\uff0c\u73b0\u5728\u4e5f\u8fd8\u53ef\u4ee5\u4f7f\u7528\u3002The following British Standards will still be applicable until they are obsolete:(a) BS 476: Part 20:1987, Fire tests on building materials and structures. Method for determination of the fire resistance of elements of construction (general principles);(b) BS 476: Part 22:1987, Fire tests on building materials and structures. Methods for determination of the fire resistance of non-load bearing elements of construction.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Code of Practice for Fire Safety in Buildings \u9999\u6e2f\u5efa\u7b51\u9632\u706b\u89c4\u83032&hellip; <a class=\"more-link\" href=\"https:\/\/www.zuranceshi.com\/?p=1597\">Continue reading <span class=\"screen-reader-text\">\u9999\u6e2f\u5efa\u7b51\u9632\u706b\u89c4\u8303 code<\/span><\/a><\/p>\n","protected":false},"author":40,"featured_media":1598,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[13],"tags":[],"_links":{"self":[{"href":"https:\/\/www.zuranceshi.com\/index.php?rest_route=\/wp\/v2\/posts\/1597"}],"collection":[{"href":"https:\/\/www.zuranceshi.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.zuranceshi.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.zuranceshi.com\/index.php?rest_route=\/wp\/v2\/users\/40"}],"replies":[{"embeddable":true,"href":"https:\/\/www.zuranceshi.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1597"}],"version-history":[{"count":1,"href":"https:\/\/www.zuranceshi.com\/index.php?rest_route=\/wp\/v2\/posts\/1597\/revisions"}],"predecessor-version":[{"id":1599,"href":"https:\/\/www.zuranceshi.com\/index.php?rest_route=\/wp\/v2\/posts\/1597\/revisions\/1599"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zuranceshi.com\/index.php?rest_route=\/wp\/v2\/media\/1598"}],"wp:attachment":[{"href":"https:\/\/www.zuranceshi.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1597"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.zuranceshi.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1597"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.zuranceshi.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}